3-4. LED Indicators on Intelligent Tap

Shown below are indication statuses of LED indicators on the Intelligent Tap when you purchased.
Location
Indicator
1
IN
2
OUT
3
IO-Link
4
ERR
*1. When the safety outputs of the F3SG-SR/PG are in the ON state, the outputs of the Intelligent Tap are in the ON state.
*2. When the safety outputs of the F3SG-SR/PG are in the OFF state, the outputs of the Intelligent Tap are in the OFF state.
In the SETTING state to make settings with the SD Manager 3, the IN and OUT indicators blink.
(IN: Yellow, OUT: Green)
For more information on the statuses of the LED indicators in the SETTING state, refer to
of F3SG-SR/PG with SD Manager 3 Connected.
Name
Color
Safety outputs of the F3SG-SR/PG
are in the ON state
Sensor status
Yellow
Outputs of the Intelligent Tap are in
the ON state (*1)
Green
Output status
Outputs of the Intelligent Tap are in
Red
the OFF state (*2)
IO-Link
Green
The Intelligent Tap is in the
LOCKOUT state, or has
communication error, DIP Switch
circuit error at startup,
Lockout
Red
communication error in the Backup
or Restoration, restoration failure,
IO-Link circuit error, power supply
voltage error or other errors
1
2
3
4
Illuminated
-
Setting with Intelligent Tap
Blinking
The F3SG-SR/PG is in the
LOCKOUT state. Or the Intelligent
Tap is waiting for Push Switch
operation (in the Backup) or the
Intelligent Tap and F3SG-SR/PG are
waiting for restart (in the Backup). Or
communication error in the Backup
or between the F3SG-SR/PG and
the Intelligent Tap. Or the
Restoration failed
The Restoration failed.
Or in the Restoration, the Intelligent
Tap has communication error, is
waiting for Push Switch operation or
transferring data, or the Intelligent
Tap and F3SG-SR/PG are waiting for
restart
Communication error between the
F3SG-SR/PG and the Intelligent Tap
Intelligent Tap communicates with
IO-Link Master. Or IO-Link circuit
error
-
4-1-4. SETTING State