Operator controls of the 3RK3 ASIsafe basic central unit
Element
RESET button
Displays of the 3RK3 ASIsafe basic central unit
Element
DEVICE
AS‑i
TEACH
SF
F-IN1, F-IN2
IN3 ... IN8
Q1, Q2
Connecting inputs and outputs
You will find further information on connecting inputs and outputs in Chapter "Wiring rules for
inputs and outputs (Page 134)."
SIRIUS 3RK3 Modular Safety System
Equipment Manual, 07/2020, NEB926253002000/RS-AC/006
Meaning
•
Error acknowledg‐
ment
•
Factory setting
•
Application of code se‐
quences
Meaning
Device status
AS‑i error
Status of the teaching of code sequences
Group error
Status of the safety-related sensor inputs
State of the standard inputs
Status of the safety-related outputs
5.1 Description of the individual modules
Description
•
Confirm the acknowledgeable errors with this button
•
Refer to Chapter "Restoring factory settings (Page 347)"
•
Refer to Chapter "Teaching the code sequences
(Page 208)"
Description of the hardware
89