Overview
3.4 A typical configuration of the subsystem with AS-Interface
1
4
①
②
③
④
⑤
⑥
⑦
Figure 3-2
Integration of the MSS 3RK3 Advanced into a higher-level, fail-safe control
The MSS 3RK3 Advanced monitors the various safety-related and non-safety-related AS-i slaves
as a safety monitor and exchanges up to 12 safety-related signals bidirectionally with an
AS‑i safety monitor.
Moreover, the MSS 3RK3 Advanced can mutually independently control up to 12 safety-related
AS-i outputs (with up to 4 outputs).
Up to 12 safety-related signals can be transmitted by the MSS 3RK3 Advanced to an F‑PLC over
the F‑Link.
40
2
6
7
PROFIBUS
AS-Interface
ASIsafe
CPU / PLC (optional)
MSS 3RK3 Advanced (the interface module is optional.)
AS-i safety monitor
AS‑i master
Data exchange with other safety monitors or MSS 3RK3 units with AS‑i interface
AS-i power section
⑪
...
Safety-related and non-safety-related AS-i slaves
A typical system configuration with MSS 3RK3 Advanced as the safety monitor
3
5
8
9
10
Equipment Manual, 07/2020, NEB926253002000/RS-AC/006
11
SIRIUS 3RK3 Modular Safety System