Byte
Message
posi‐
tion
8
1
Start condition not fulfilled
8
... 8
Reserved=0
2
7
SIRIUS 3RK3 Modular Safety System
Equipment Manual, 07/2020, NEB926253002000/RS-AC/006
Meaning
is set if:
A sensor test was not executed in the case
of an active startup test function
A discrepancy condition violation is
present
The value "1" is not present simultaneously
at all available (parameterized) function
inputs (IN1, ...)
A cross-circuit is present in the case of
cross-circuit monitoring
7.6 Diagnosis using AS-Interface (CTT2 protocol)
Element status
Diagnostics / service
Cyclic data
315