Message
Safety sensor triggered
Protective door closed
Lock engaged
Lock released
Cross-circuit at input x
Start signal duration invalid
Start condition not fulfilled
Start override active
Feedback circuit signal and
switching status do not match
Protective door opened when
interlock was active
Interlock not possible because
the protective door is open
SIRIUS 3RK3 Modular Safety System
Equipment Manual, 07/2020, NEB926253002000/RS-AC/006
Meaning
The safety sensor has been actuated. This
message is automatically reset if the value
"1" is present for all function inputs moni‐
tored (set as part of configuring).
The protective door is closed.
The lock is engaged.
The lock is released
A cross-circuit was detected at input x.
Only with start type "Monitored start":
The start signal time monitoring element
detected a violation.
is set if:
A sensor test was not executed in the
case of an active startup test function
A discrepancy condition violation is
present
The value "1" is not present simultane‐
ously at all available (parameterized)
function inputs (IN1, ...)
A signal sequence violation is present
A cross-circuit is present in the case of
cross-circuit monitoring
The start override time is running.
The feedback circuit signal does not match
the interlock status
The protective door opened when inter‐
lock was active.
Interlock not possible because the protec‐
tive door is open.
7.3 Diagnostics with LEDs
LED response
SF-LED on cen‐
Input LEDs on central unit or
tral unit
expansion module
The IN LEDs of the sensor are
off.
The IN2-LED is green on input
type NCNO.
The IN LEDs of the sensor are
green.
The IN2-LED is off on input
type NCNO.
red
The IN LEDs of the sensor are
flashing green.
red
The corresponding IN LED of
the input that is connected on
the FEEDBACK_LOCK function
input flashes green if in the
logic there is no more than
one negation between the el‐
ement input and the input cell.
red
The corresponding IN LEDs of
the sensor (protective door
monitoring) are flashing
green.
flashes red
The corresponding IN LEDs of
the sensor (protective door
monitoring) are flashing
green.