Byte
Meaning
58
SC configuration error
2
58
SC process data exchange
3
stopped
58
4
SC communication OK
58
5
... 89
Reserved = 0
Diagnosed elements
90 ... 91
Element number for group
error from user program
92 ... 93
Reserved = 0
94 ... 95
Element number for group
prewarning from user pro‐
gram
96 ... 199
Reserved = 0
✓: Supported
‑: Not supported
SIRIUS 3RK3 Modular Safety System
Equipment Manual, 07/2020, NEB926253002000/RS-AC/006
DS92 (device messages)
Note
An expansion module cannot be
addressed, or an unaddressed ex‐
pansion module is installed.
Expansion modules are not in‐
volved in cyclic data exchange
(e.g. system in configuring mode)
Expansion modules in cyclic data
exchange
Element number of the first detec‐
ted element of the processing se‐
quence for which a group error is
pending:
[0]: for now error
[1 ... 32767]: element no.
Element number of the first detec‐
ted element of the processing se‐
quence for which a group error is
present:
[0]: for now error
[1 ... 32767]: element no.
7.11 Description of the diagnostic data sets
3RK3 Basic
Error cat‐
DP error
egory
number
SF
F24, F27
Diagnostics / service
3RK3 Advanced
3RK3 ASIsafe
Error cat‐
DP error
egory
number
SF, BF
F24, F27
363