4.5 Wiring of the MSS 3RK3 Basic
Step
Action
5
Connect the light curtain to the 3RK3 Basic
central unit, with
•
Output 1 of the light curtain: Terminal
IN1
•
Output 2 of the light curtain: Terminal
IN2
Note:
Please refer here to the operating instruc‐
tions for the light curtain.
6
Connect the two-hand operator panel to the
3RK3 Basic central unit, with:
•
NC pushbutton 1: Terminal T2/IN6
NO pushbutton 1: Terminal T1/IN5
•
NC pushbutton 2: Terminal T2/IN8
NO pushbutton 2: Terminal T1/IN7
7
Connect the Start pushbutton on the expan‐
sion module 2/4 F‑DI 2F‑DO, with:
•
NO contact: Terminal T1/IN1
66