Protective circuit for outputs that switch inductive loads
Increasing the fault reaction time
Can Cause Death, Serious Injury, or Property Damage.
Note that the (fault) reaction time is made longer by the protective circuit.
Loss of the safety function
Can Cause Death, Serious Injury, or Property Damage.
In the case of inductive loads, the external protective circuit must be arranged in parallel with
the load. Connection in parallel with the outputs can prevent shutdown of the machine or
process.
The diagrams show examples of protective circuits
for inductive loads. You will find details of protec‐
tive circuits from SIEMENS in the catalog and the
relevant documentation.
SIRIUS 3RK3 Modular Safety System
Equipment Manual, 07/2020, NEB926253002000/RS-AC/006
WARNING
WARNING
6.2 Selection of sensors and actuators
Example:
Protective circuit for an inductive load