System Functions
Figure 10.95: Example of the Dialog Box for Active PLC Change
2. Change of Master Workstation/CPU
To change the master WS/CPU:
– press and hold for a few seconds dark-green softkey of the slave WS/CPU on the Mimic Diagram;
– press OK in the opened dialog box to apply the control transfer (see Figure 10.96).
Figure 10.96: Example of the Dialog Box for Control Transfer to Another WS/CPU
3. Control Transfer to MCP/PCP
To transfer control to another MCP (PCP):
– press and hold for a few seconds dark-green softkey of the slave MCP/PCP on the Mimic Diagram;
– press OK in the opened dialog box to apply the control transfer (see Figure 10.96).
Figure 10.97: Example of the Dialog Box for Control Transfer to Another Control Panel
10.12.2 Component State Tables
1. Thruster and Power system component states table.
The following data are displayed for each thruster:
– "Run", "Rdy", "Flt" indicators;
– circuit breaker (CB) state: On/Off;
– "Mode" text indicator (option) (see Section 6.1.3, page 105 for details).
The following data are displayed for each Power system component: "Run" indicator and CB state: On/Off.
TB state (On/Off) is displayed for each tie breaker.
2. System state table. States of the following components are displayed:
Doc. 000.JDP-10000-OME, rev.3.3.13/"2102.$–17A-Advanced"
(a) Master WS Change
(a) Control Transfer to MCP
(b) Master CPU Change
(b) Control Transfer to PCP
236