NAVIS NavDP 4000 Series Operation Manual page 137

Dynamic positioning & independent joystick control system
Table of Contents

Advertisement

Sensors
If draft/load sensor is present, in "all sensors window" loading and draft info is shown (see figure 7.18). If there is no
draft sensor, but NAVIS NavDP 4000 is configured with "variable draft" option, manual input of draft/loading is allowed
(see Sections 7.3.5.2, page 136, 7.3.5.4, page 137).
The top of the Draft Details window is shown in Figure 7.19.
7.3.5.2 Manual draft value
Operator can change mean draft value manually. Optionally, operator input not draft but loading in tons (it is config-
ured for each system).
Press Change softkey to show the draft/loading input dialog – see Figure 7.20.
When operator press Ok, value of displacement and loading corresponded the entered data are updated.
Figure 7.20: Input Manual Draft/Loading Value Dialog Example
7.3.5.3 Used draft
Used draft is sensor processed data or manual value. Press Manual/Sensor softkey to select the source of draft
information.
When there are some problems with draft sensor and processing status of draft sensor is red, source is automatically
switched to "manual".
Indicator
shows which data is used – sensor or manual.
Doc. 000.JDP-10000-OME, rev.3.3.13/"2102.$–17A-Advanced"
Figure 7.18: Draft sensor. Fragment of sensors window
Figure 7.19: Draft sensor details
136

Advertisement

Table of Contents
loading

Related Products for NAVIS NavDP 4000 Series

This manual is also suitable for:

Navdp 4011Navdp 4001Navdp 4022Navdp 4002

Table of Contents