Available languages

Available languages

Level 1: TIG set-up parameters

Accessing

-
-
-
Important! The first parameter to be displayed is always the one that was the last to be
selected the last time the set-up menu was accessed.
Selecting and
-
altering the set-
up parameter
-
Saving and
-
exiting
SPt ..... Spot-welding time ... OFF / 0.1 to 9.9 s, factory setting: OFF
Available set-up
parameters
If a value has been set for the "SPt" set-up parameter, the operating mode "2-step
mode" (2) will have the function of the spot-welding mode.
tAC ..... Tacking ... Duration of the pulsed welding current at the beginning of the
Important! The tacking function is only available for the TIG-DC welding process.
"ON" position ........... The pulsed welding current remains in effect up until the end of the
Value 0.1 to 9.9 s .... The pre-set time begins with the upslope phase. After the end of
"OFF" position ......... The tacking function is deactivated
Please see the section headed "TIG welding" for a description of the tacking function.
Press the "Mode" button (1) to select either 2-step mode (2) or 4-step mode (3)
(2)
(3)
(1)
While pressing and holding the Store button (13), press the "Mode" button (1)
The first set-up parameter is displayed (e.g. "SPt")
Select the desired set-up parameter with the parameter selection buttons (8) and
(9).
Alter the value of the set-up parameter with the adjusting dial (7)
Press the Store button (13)
Spot-welding status indicator: Remains lit up as long as a value has been
specified for the spot-welding time.
tacking operation ... OFF / 0.1 to 9.9 s / ON (pulsed welding current remains in
effect up until the final current phase I
Factory setting: OFF
tacking operation
the pre-set time period, welding continues at constant amperage,
and any pulsing parameters that may have been set are available.