Troubleshooting - Fronius TransTig 2200 Operating Instructions Manual

Digital tig power source
Hide thumbs Also See for TransTig 2200:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting

General remarks
The digital power sources are equipped with an intelligent safety system. This means
that apart from the fuse for the coolant-pump, it has been possible to dispense with
melting-type fuses entirely. After a possible malfunction or error has been remedied, the
power source can be put back into normal operation again without any melting-type
fuses having to be changed.
Displayed
If any error message that is not described here appears on the displays, then the fault is
service codes
one that can only be put right by a service technician. Make a note of the error message
shown in the display, and of the serial number and configuration of the power source,
and get in touch with our after-sales service, giving them a detailed description of the
error.
no | Prg
Cause:
Remedy:
tP1 | xxx, tP2 | xxx, tP3 | xxx, tP4 | xxx, tP5 | xxx, tP6 | xxx
Cause:
Remedy:
tS1 | xxx, tS2 | xxx, tS3 | xxx
Cause:
Remedy:
tSt | xxx
Cause:
Remedy:
Err | 051
Cause:
Remedy:
Err | 052
Cause:
Remedy:
no | IGn
Cause:
Remedy:
Warning! An electric shock can be fatal. Before opening up the power source,
switch it off, unplug it from the mains and put up a clearly legible and easy-to-
understand warning sign to stop anybody inadvertently switching the machine
back on again. If necessary, discharge the electrolytic capacitors.
No pre-programmed program has been selected
Select a pre-programmed program
Over-temperature in the primary circuit of the power source
Allow the power source to cool down
Over-temperature in the secondary circuit of the power source
Allow the power source to cool down
Over-temperature in the control circuit
Allow the power source to cool down
Mains undervoltage: The mains voltage has dropped below the tolerance
range (-30% / +15%)
Check the mains voltage
Mains overvoltage: The mains voltage has risen above the tolerance range
(-30% / +15%)
Check the mains voltage
"Ignition time-out" function is active: No current started flowing before the
end of the time specified in the set-up menu. The safety cut-out of the
power source has been triggered.
Press the torch trigger repeatedly; clean the surface of the workpiece; if
necessary, increase the time-period specified in "Set-up menu: Level 2"
before the safety cut-out is triggered.