Program Level Preferences; Access; Select And Change Setup Parameters; Available Tig Parameters - Fronius MagicWave 2600 Manual

Tig power source
Hide thumbs Also See for MagicWave 2600:
Table of Contents

Advertisement

"Program level preferences"

Access

1
2
3
4
Select and
1
change setup
2
parameters
Available TIG
NOTE!
parameters
If problems occur with sensitive devices in the immediate vicinity, increase the welding
parameter HFt to up to 0.4 s.
GAS
G - L
G - H Gas-High
UPS
SCU
Select the desired operating mode TIG/Electrode
Switch off power source
Switch on the power source while holding down the operating mode (3) or process
(4) button.
Release mode (3) or process (4) button
Select the desired parameter using the operating mode (3) or process (18) button
Change the parameter value using the torch trigger
Gas pre-flow
Unit: Seconds
Setting range: 0 - 20
Factory setting: 0.4
Gas-Low
Gas post-flow at minimum welding current (minimum gas post-flow time)
Unit: Seconds
Setting range: 2 - 26
Factory setting: 5
Gas post-flow time at maximum welding current
Unit: Seconds
Setting range: 2 - 26
Factory setting: 15
The setting value for G-H only applies if the maximum welding current is actually
set. The actual value results from the momentary welding current. At medium
welding current, for example, the actual value is half the set value for G-H.
UpSlope
Time for transition from starting current I
Unit: %
Setting range: DC: 0 - 100 / AC: 30 - 100 of the main current I
Factory setting: DC: 29 / AC: 50
Start-Current
Starting current
Unit: Seconds
Setting range: 0 - 20
Factory setting: 0.4
to welding current I
S
H
H
57