Communication Cable Specifications - YASKAWA SI-C3 Technical Manual

Ac drive option cc-link
Hide thumbs Also See for SI-C3:
Table of Contents

Advertisement

5 Installation Procedure
A - Keypad connector tab
B - Keypad connector
C - Drive front cover
Figure 5.14 Install the LED Status Ring board, Front Cover, and Keypad
7.
Set drive parameters in

Communication Cable Specifications

Use only CC-Link dedicated communication cable. The Yaskawa warranty does not cover other cable types. For
more information on cables, refer to the CC-Link website at http://www.cc-link.org/.
Yaskawa recommends using CC-Link cables suitable for the conditions listed in the following table.
Item
Cable Type
External Diameter
Drain Wire
Conductor Resistance (20°C (68°F))
Insulation Resistance
Voltage Tolerance
Capacitance (1 kHz)
Electrical
Characteristics
Impedance
Attenuation (20°C (68°
F))
A - Sheath
B - Shield
C - Aluminum tape
D - DG (yellow)
E - Ground
20
Related Drive Parameters on page 23
Table 5.2 Communication Cable Requirements
1 MHz
5 MHz
1 MHz
5 MHz
Figure 5.15 CC-Link Cable Diagram
D - Keypad
E - LED Status Ring board
for correct option performance.
Specifications
triple-core shielded twisted-pair cable
8.0 mm maximum
20 lines/0.18 mm or 24 lines/0.18 mm
37.8 Ω/km
10000 MΩ・km or greater
500 Vdc, 60 s
60 nF/km maximum
110 ±15 Ω
110 ±6 Ω
1.6 dB/100 m maximum
3.5 dB/100 m maximum
F - Drain (solid/non-stranded)
G - DB (white)
H - DA (blue)
I - Drain (stranded wire)