8 CC-Link Data List
Signal
Name
RY17
Term MA/MB-MC Function
RY18, 19
Reserved
RY1A
Fault Reset
RY1B - 1F
Reserved
*1
Terminals are different for different drive models. Refer to
for more information.
Note:
Although RYF is triggered by the rising edge of the signal, they are otherwise enabled depending on the value that is input.
D1000 → PLC
Signal
Name
RX0
During Run/During Stop
RX1
During Regeneration
RX2
Terminal M1-M2 Function
RX3
During Run (Converter Ready)
RX4
Reserved
RX5
Uv [Undervoltage]
RX6
Terminal P1-PC Function
RX7
Terminal P2-PC Function
Momentary Power Loss Ride-
RX8
Thru/Power Loss Recovery
RX9
ComCtrlstatus/NetCtrlstatus
RXA
CC-Link Option Fault
RXB
During Active Current Limit
RXC
Obtain Monitor Data
RXD
Alarm
RXE
Fault
Command Code Execute
RXF
Complete
RX10
During Reset Signal Input
RX11
oPE Error
AUv [Power Supply
RX12
Undervoltage]
RX13 - 19
Reserved
RX1A
Error
RX1B
Remote Station Ready
RX1C - 1F
Reserved
*1
Terminals are different for different drive models. Refer to
for more information.

Remote Register

Note:
Remote register data varies between drives and D1000 that support this option.
32
Fault Contact Output
Resets a D1000 fault.
Table 8.4 Remote I/O List (D1000 → PLC)
ON: During Run
OFF: Stop
ON: During Regeneration
Multi-function output: H2-01 [Terminal M1-M2 Function Selection]
*1
Multi-function output: H2-02 [Terminal P1-PC Function Selection]
*1
Multi-function output: H2-03 [Terminal P2-PC Function Selection]
Communication error between D1000 and CC-Link device
ON: Monitor data has been updated.
ON: Displayed after the specified command code has been executed.
RXF signal switches OFF when the RYF command is no longer present.
ON: Fault occurred on the D1000 side.
ON: D1000 is ready to operate.
Description
-
-
Terminals that Change depending on the Model of the Drive on page 35
Description
-
-
-
-
-
-
-
-
-
-
-
-
-
Terminals that Change depending on the Model of the Drive on page 35
YASKAWA SIEP C730600 83E CC-Link Technical Manual
Comments (Default)
-
-
-
-
Comments (Default)
-
-
H2-01 = 25
-
-
-
H2-02 = 26 [During MC ON]
H2-03 = 6 [Converter Ready]
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-