Drive Fault Contents - YASKAWA SI-C3 Technical Manual

Ac drive option cc-link
Hide thumbs Also See for SI-C3:
Table of Contents

Advertisement

Monitor Code (Hex.)
1000
Number of pulse 1 speed detection
1001
Number of pulse 2 speed detection
1002
Cumulative operation time
1003
Watt-hour output (lower digits)
1004
Watt-hour output (upper digits)
1010
Alarm code
1011
Fault code
1012
Reserved
1013
Fault contents 1
1014
Fault contents 2
1015
Fault contents 3
1016
Fault contents 4
1017
Fault contents 5
101C
CPF contents 1
101D
CPF contents 2
101E
CPF contents 3
101F
Alarm contents 1
1020
Alarm contents 2
1021
Alarm contents 3
1022
Alarm contents 4
1023
Alarm contents 5
1027
Output frequency at previous fault
1028
Output current at previous fault
1029
Output voltage at previous fault
102A
Cumulative operation time at previous fault
*1
Terminals are different for different drive models. Refer to
for more information.
*2
Refer to
Drive Fault Contents on page 45

Drive Fault Contents

Extended Command Code
(Monitor Code) (Hex.)
Fault contents 1
120 (1013)
YASKAWA SIEP C730600 83E CC-Link Technical Manual
Name
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
or
Drive Alarm Contents on page 48
Table 10.4 Drive Fault Contents
Name
BIT
0
Reserved
1
Uv1 [DC Bus Undervoltage]
2
Uv2 [Control Power Undervoltage]
3
Uv3 [Soft Charge Answerback Fault]
4
SC [Short Circuit/IGBT Failure]
5
Reserved
6
oC [Overcurrent]
7
ov [Overvoltage]
8
oH [Heatsink Overheat]
9
oH1 [Heatsink Overheat 1]
A
oL1 [Motor Overload]
B
oL2 [Drive Overload]
C
oL3 [Overtorque Detection 1]
Terminals that Change depending on the Model of the Drive on page 35
for information on fault contents.
10 CC-Link Code Numbers List
Comments
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Fault Code (U2, U3) (Hex.)
-
-
0002
0003
0004
0005
-
0007
0008
0009
000A
000B
000C
000D
45

Advertisement

Table of Contents
loading