10 CC-Link Code Numbers List

10
CC-Link Code Numbers List
Note:
Command Codes, Extended Command Codes, Monitor Codes and Fault/Alarm Codes vary between drives and D1000 that support this
option.

Drive Codes

Drive Codes
Command Code (Hex.)
1181
Read Run Command Source
1180
Read Frequency Reference Source
2181
Write Run Command Source
2180
Write Frequency Reference Source
0074
Fault History 1
0075
Fault History 2
0076
Fault History 3
0077
Fault History 4
0078
Fault History 5
0079
Fault History 6
007A
Fault History 7
0080
Fault History 8
0081
Fault History 9
0082
Fault History 10
006D
Read Frequency Reference (RAM)
006E
Read Frequency Reference (EEPROM)
007B
Read LOCAL/REMOTE status
00FB
Write LOCAL/REMOTE status
00ED
Write Frequency Reference (RAM)
00EE
Write Frequency Reference (EEPROM)
-
Read Parameters
-
Parameter Settings
00F4
Clear All Fault Contents
00FD
Reset Drive
40
Table 10.1 Drive Command Codes List
Name
0: Keypad
1: Control Circuit Terminals (sequencer input)
2: MEMOBUS/Modbus Communications
3: Option
0: Keypad
1: Control Circuit Terminals (analog input)
2: MEMOBUS/Modbus Communications
3: Option
4: Pulse Train Input
0: Keypad
1: Control Circuit Terminals (sequencer input)
2: MEMOBUS/Modbus Communications
3: Option
0: Keypad
1: Control Circuit Terminals (analog input)
2: MEMOBUS/Modbus Communications
3: Option
4: Pulse Train Input
Reads the contents from U3-01 [1st MostRecent Fault].
Reads the contents from U3-02 [2nd MostRecent Fault].
Reads the contents from U3-03 [3rd MostRecent Fault].
Reads the contents from U3-04 [4th MostRecent Fault].
Reads the contents from U3-05 [5th MostRecent Fault].
Reads the contents from U3-06 [6th MostRecent Fault].
Reads the contents from U3-07 [7th MostRecent Fault].
Reads the contents from U3-08 [8th MostRecent Fault].
Reads the contents from U3-09 [9th MostRecent Fault].
Reads the contents from U3-10 [10th MostRecentFault].
Reads the drive's frequency reference from RAM.
Reads the frequency reference from EEPROM.
Bit 0: 0 = Frequency reference from CC-Link is enabled.
Bit 1: 0 = FWD/REV Run command from CC-Link is enabled.
Bit 8: 1 = During Stall Prevention
Bit 0: 0 = Frequency reference from CC-Link is enabled.
Bit 1: 0 = FWD/REV Run command from CC-Link is enabled.
When power is cycled, however, the source is determined by b1-01 [Frequency
Reference Selection 1] and b1-02 [Run Command Selection 1]. If one of the multi-
function relay input terminals is set to switch the source of the Run command (H1-xx =
2), then the Run command and frequency reference will be supplied by b1-01 and b1-02
when that terminal is open, and b1-15 [Frequency Reference Selection 2] and b1-16
[Run Command Selection 2] when that terminal is closed.
Writes the frequency reference for the drive to RAM.
Writes the frequency reference and all parameter values to EEPROM.
Adds 1000 (Hex.) to the MEMOBUS/Modbus register number.
Master executes commands by adding 2000 (Hex.) to the MEMOBUS/Modbus register
number. Conversion takes place on the option side.
9696 (Hex.): Clear fault history
9696 (Hex.): Fault reset
Description
YASKAWA SIEP C730600 83E CC-Link Technical Manual