Number
Name
CH2 operation
SD1904
mode monitor
CH2 counter type
SD1905
monitor
CH2 selected
SD1906
counter function
SD1907
CH2 error code
CH2 warning
SD1908
code
374
Meaning
This register stores a value indicating the operation
mode for high-speed counter of CH2 set by the
parameter.
• 0: Unused
CH2 operation
• 1: Normal mode
mode monitor
• 2: Frequency measurement mode
• 3: Rotation speed measurement mode
• 4: Pulse measurement mode
• 5: PWM output mode
• This register stores a value indicating the counter
type for high-speed counter of CH2 set by the
parameter.
CH2 counter type
• Counter selection is disabled (fixed at "0") when a
monitor
value stored to CH2 operation mode monitor
(SD1904) is other than "1" (normal mode).
• 0: Linear counter
• 1: Ring counter
• This register stores a value indicating the selected
counter function for high-speed counter of CH2 set
by the parameter.
• Counter selection is disabled (fixed at "0") when a
value stored to CH2 operation mode monitor
CH2 selected
(SD1904) is other than "1" (normal mode).
counter function
• 0: Count disabling function
• 1: Latch counter function
• 2: Sampling counter function
• 3: Count disabling/preset function
• 4: Latch counter/preset function
This register stores the error code of an error occurred
CH2 error code
in CH2.
This register stores the warning code of a warning
CH2 warning code
occurred in CH2.
Explanation
Corre-
Corre-
sponding
Set by
sponding
(When Set)
ACPU
D9
S
(Every END
New
LCPU
processing)
CPU