Mitsubishi MELSEC L Series User Manual page 195

Hide thumbs Also See for MELSEC L Series:
Table of Contents

Advertisement

Error
Code
Error Contents and Cause
(SD0)
[OPERATION ERROR]
• The block data that crosses over the boundary
between the internal user device and the
extended data register (D) or extended link
register is specified (including 32-bit binary, real
number (single precision, double precision),
4101
indirect address, and control data).
■Collateral information
• Common information: Program error location
• Individual information:-
■Diagnostic Timing
• When instruction executed
[OPERATION ERROR]
In a multiple CPU system, the link direct device
(J \ ) was specified for the network module
under control of another station.
■Collateral information
• Common information: Program error location
• Individual information:-
■Diagnostic Timing
• When instruction executed
[OPERATION ERROR]
• The module No./network No. /station No.
specified for the dedicated instruction is wrong.
• The link direct device (J \ ) setting is incorrect.
• The module No./network No./number of
4102
character strings exceeds the range that can be
specified.
■Collateral information
• Common information: Program error location
• Individual information:-
■Diagnostic Timing
• When instruction executed
[OPERATION ERROR]
The character string (" ") specified by a dedicated
instruction cannot be used for the character string.
■Collateral information
• Common information: Program error location
• Individual information:-
■Diagnostic Timing
• When instruction executed
[OPERATION ERROR]
The configuration of the PID dedicated instruction
is incorrect.
■Collateral information
4103
• Common information: Program error location
• Individual information:-
■Diagnostic Timing
• When instruction executed
[OPERATION ERROR]
PLOADP/PUNLOADP/PSWAPP instructions were
executed while setting program memory check.
■Collateral information
4105
• Common information: Program error location
• Individual information:-
■Diagnostic Timing
• When instruction executed
[OPERATION ERROR]
33 or more multiple CPU dedicated instructions
were executed from one CPU module.
■Collateral information
4107
• Common information: Program error location
• Individual information:-
■Diagnostic Timing
• When instruction executed
Corrective Action
Read common information of the error using the
programming tool to identify the numeric value
(program error location). Check the error step
corresponding to the value, and correct it as
necessary.
• Delete from the program the link direct device
which specifies the network module under
control of another CPU.
• Using the link direct device, specify the network
module controlled by the own station.
Read common information of the error using the
programming tool to identify the numeric value
(program error location). Check the error step
corresponding to the value, and correct it as
necessary.
• Delete the setting for the program memory
check.
• When using the program memory check, delete
PLOADP/PUNLOADP/PSWAPP instructions.
Using the multiple CPU dedicated instruction
completion bit, provide interlocks to prevent one
CPU module from executing 33 or more multiple
CPU dedicated instructions.
APPENDICES
LED Status
Corresponding CPU
CPU Status
QnU
LCPU
RUN:
Off/On
ERR.:
Flicker/On
CPU Status:
Stop/
*1
Continue
*8
Q00/Q01
*8
Qn(H)
QnPH
*18
QnU
QCPU
LCPU
RUN:
Off/On
ERR.:
Flicker/On
CPU Status:
QnU
Stop/
LCPU
*1
Continue
Q00J/Q00/Q01
Qn(H)
QnPRH
QnU
LCPU
RUN:
Off/On
ERR.:
*12
Flicker/On
QnPH
CPU Status:
Stop/Continue
RUN:
*8
Off/On
Q00/Q01
ERR.:
*8
Qn(H)
Flicker/On
QnPH
Q00UCPU
CPU Status:
Q01UCPU
Stop/
Q02UCPU
*1
Continue
193