Mitsubishi MELSEC L Series User Manual page 269

Hide thumbs Also See for MELSEC L Series:
Table of Contents

Advertisement

ACPU
Special
Special
Special
Relay after
Relay for
Relay
Conversion
Modification
M9006
SM1006
-
M9007
SM1007
-
M9008
SM1008
SM1
M9009
SM1009
SM62
M9011
SM1011
SM56
M9012
SM1012
SM700
M9016
SM1016
×
M9017
SM1017
×
M9020
SM1020
-
M9021
SM1021
-
M9022
SM1022
-
M9023
SM1023
-
M9024
SM1024
-
M9025
SM1025
-
M9026
SM1026
-
M9028
SM1028
-
M9029
SM1029
×
Name
Meaning
OFF : Normal
Battery low
ON : Battery low
OFF : Normal
Battery low latch
ON : Battery low
Self-diagnosis
OFF : No error
error
ON : Error
OFF : No F number
Annunciator
detected
detection
ON : F number
detected
Operation error
OFF : No error
flag
ON : Error
OFF : Carry OFF
Carry flag
ON : Carry ON
Data memory
OFF : lgnored
clear flag
ON : Output claered
Data memory
OFF : lgnored
clear flag
ON : Output claered
User timing
clock No.0
User timing
clock No.1
User timing
clock No.2
User timing
n2 scan
n2 scan
clock No.3
n1 scan
User timing
clock No.4
OFF : Ignored
Clock data set
ON : Set request
request
present used
OFF : No error
Clock data error
ON : Error
Clock data read
OFF : Ignored
request
ON : Read request
OFF : Batch
Batch
processing not
processing of
conducted
data
ON : Batch
communications
processing
requests
conducted
Details
• This relay turns on when the battery voltage drops
to or below the specified.
• It turns off when the battery voltage returns to
normal.
• This relay turns on when the battery voltage drops
to or below the specified.
• This relay remains on even after the battery
voltage returns to normal.
This relay turns on if an error is detected by self-
diagnostics.
• This relay turns on when the OUT F or SET F
instruction is executed.
• It turns off when the SD1124 value is cleared to
zero.
• This relay turns on when an operation error occurs
during execution of an application instruction.
• This relay remains on even after the system
returns to normal.
Carry flag used in application instruction.
When SM1016 turns on and remote RUN mode is
activated from a computer, all the data memory
including the latch range (except for the special relay
and special register) is cleared.
When SM1017 turns on and remote RUN mode is
activated from a computer, all the data memory that
is not latched (except for the special relay and
special register) is cleared.
• This relay repeatedly turns on and off at the
specified scan intervals.
• When the CPU module is powered on or reset, this
relay is set to on from off to start the clock. Set the
intervals of on/off by DUTY instruction.
DUTY
n1 n2 SM1020
•n1: On scan interval
•n2: Off scan interval
When SM1020 to SM1024 are specified for the
DUTY instruction in programs, if the CPU type is
changed from the High Performance model QCPU
or Process CPU to the Universal model QCPU or
LCPU, they are replaced with SM420 to SM424.
(For the Universal model QCPU and LCPU,
SM1020 to SM1024 cannot be specified.)
Clock data stored in SD1025 to SD1028 are written
to the CPU module after the END instruction
execution in the scan where SM1025 is turned on.
This relay turns on if an error occurs in the clock data
(SD1025 to SD1028), and is off while there is no
error.
This relay is turned on to read clock data and store
them as BCD values into SD1025 to SD1028.
• When this relay is turned on in the program, all the
data communication requests accepted during one
scan are processed in the END processing of that
scan.
• The batch processing of data communication
requests can be turned on or off during running.
• The default is OFF (processed one at a time for
each END processing in the order in which data
communication requests are accepted).
APPENDICES
Corre-
sponding
CPU
Qn(H)
QnPH
*1
QnU
LCPU
Qn(H)
QnPH
*1
QnU
Qn(H)
QnPH
A
Qn(H)
QnPH
*1
QnU
LCPU
Qn(H)
QnPH
267