WAGO-I/O-SYSTEM 750
750-471 4AI U/I Diff Galv
10.1.2.1

All PROFIBUS DP and PROFINET IO Fieldbus Couplers/Controllers

The following assignment applies to the parameters of the I/O module when
using PROFIBUS DP and PROFINET IO fieldbus devices.

Table 47: Specific Module/Channel parameters for 75x-461/003-000

GSD file
Parameter
Number format
Siemens
S5 format
Input filter frequency
Signal type Channel x
(x = 0...3)
Input filter
Channel x
(x = 0...3)
User scaling
Offset
Gain
)
*
Default setting
)
**
The resolution 1/16384 is already taken into account in WAGO-I/O-CHECK.
All manuals and user guides at all-guides.com
Value
Twos Complement*
Sign magnitude
)
disabled*
activated
)
50 Hz*
60 Hz
disabled
0 - 10 V
+/ − 10 V
0 - 20 mA
)
4 - 20 mA*
3,6 - 21,0 mA
(Namur NE43)
+/− 20 mA
+/− 200 mV
)
disabled*
activated
)
disabled*
activated
)
− 32768 ... 0*
... 32767
)
− 32768 ... 16384*
32767
WAGO-I/O-CHECK
Checkbox
)
Number format
Siemens
S5 format
Input filter frequency
Signal type
Input filter
User scaling
Offset
...
Gain
Appendix
83
Value
)
Twos Complement*
Sign magnitude
)
Off*
On
)
50 Hz*
60 Hz
Channel disabled
0 - 10 V
+/ − 10 V
0 - 20 mA
)
4 - 20 mA*
3,6 - 21,0 mA
(Namur NE43)
+/− 20 mA
+/− 200 mV
)
Off*
On
)
Checkbox disabled*
Checkbox activated
)
− 32768 ... 0*
...
32767
)