WAGO I/O SYSTEM 750
750-498 8AI; TC; Adjust
For the PROFINET IO fieldbus couplers 750-375(/025-000) and
750-377(/025-000) the channel´s user limits can be adjusted via GSD, too. On
input values falling below or exceeding those limits, a respective process alarm
will be issued.
Figure 38: Example of the 750-375(/025-000) and 750-377(/025-000) fieldbus coupler
parameterization dialog
9.1.2.1

All PROFIBUS DP and PROFINET IO Fieldbus Couplers

The following assignment applies to the parameters of the I/O module when
using PROFIBUS DP and PROFINET IO fieldbus devices.

Table 51: Specific module / channel parameters for 750-498

GSD File
Description
Number
format
Notch filter
Sensor type
Channel x
Value
*)
Twos complement
Sign magnitude
deactivated
*)
50 Hz
60 Hz
50/60 Hz
Type E [DIN EN 60584-1]
Type N [DIN EN 60584-1]
WAGO-I/O-CHECK
Selection box Value
Number
Twos complement
format
Sign magnitude
Notch filter
deactivated
*)
50 Hz
60 Hz
50/60 Hz
Sensor type
Type E [DIN EN 60584-1]
Type N [DIN EN 60584-1]