Agilent Technologies 5DX 5000 Series Installation Manual page 59

Table of Contents

Advertisement

Figure B-2
PDU Outlets
8
4
Outlet 1 — Laser Displacement Unit 2
Outlet 2 — Laser Displacement Unit 1
Outlet 3 —
Outlet 4 —
Outlet 5 — X Motor Servo Module
Outlet 6 — R Motor Servo Module
Outlet 7 — Y1 Motor Servo Module
Outlet 8 — Y2 Motor Servo Module
NOTE
5DX systems have been pre-wired with a cord and plug. The
local electrician will need to install a suitable outlet where the
plug can be inserted.
NOTE
Wire the PDU only as shown in the following drawings.
Terminals numbered the same are the same electrically but for
proper load balancing and current distribution, follow the wiring
diagrams.
Agilent 5DX Installation
!
7
6
5
3
2
1
!
50 Hz
60 Hz
100V
208V
120V
220V
127V
230V
200V
240V
Wiring Configuration B-51