Xylem WEDECO SMOevo PLUS Series Original Manual page 72

Ozone generating system
Table of Contents

Advertisement

Barometric
pressure
Temperature
and humidity
Ambient air temperature
Ambient air temperature, average
Humidity, rel.
Altitude, above sea level
Ambient air must be free from aggressive substances.
1)
Higher ambient temperatures are possible with special option.
2)
For higher altitudes above sea level consulte Wedeco for assistance.
With regard to EMC emission standards, the system meets the protection requirements for
the industrial sector without restrictions.
When operated in residential, office, business and small scale industrial
sectors, special structural engineering shielding measures may have to be
taken in order to prevent radio interference.
Contact your Wedeco Service for assistance.
Refer to Chapter Contact Addresses.
Special
Openings to other rooms, e. g. pipe or cable channels must be gas tight or
Safety
included in the monitoring process. Openings to rooms in lower levels or
downward stairs are particularly at risk and therefore must imperatively be
included in the safety concept and the monitoring process.
Manual_SMOevoPLUS_eng_01.2019.doc
The manometers used in the generator indicate the pressure of the
system in relation to the barometric air pressure in the operating
room.
Ensure that there is no inadmissible heating-up of the operating
room due to the dissipated heat of the generator.
Operating Data.
Air-conditioned rooms are recommended.
The following table shows the values admissible for the ozone
system:
Ambient air conditions
1)
Ensure that the air humidity does not exceed 90% during
continuous operation, higher values are possible for brief
periods (<1h). Ensure that there is no condensation resulting
from moisture (dew) in or on the system.
Manual Ozone Generating System SMOevo
Installation and Initial Start Up
10°C – 35°C
20°C
< 90%
< 500 m
PLUS
Refer to Chapter
1)
1)
41°F – 95°F
68°F
<760 ft
page 72 of 179