Xylem WEDECO SMOevo PLUS Series Original Manual page 140

Ozone generating system
Table of Contents

Advertisement

Message
Message shown on the display
No.
SYS:DI1.3 Alarm overload PSU
12
SYS:DI1.4 Alarm overload PSU / Overload
13
air condition
SYS:DI1.5 Alarm fault external auxiliary
14
Manual_SMOevoPLUS_eng_01.2019.doc
Manual Ozone Generating System SMOevo
Description /
Possible Cause
Current consumption too high.
Incorrect limit value.
Motor protective circuit breaker
defective.
Current consumption too high.
Incorrect limit value.
Motor protective circuit breaker
defective.
Overload Rittal air condition units.
Eco mode activated on the Rittal
air-condition unit.
Fault message from external
auxiliary.
Cable break.
Incorrect wiring.
PLUS
Troubleshooting
Countermeasures
Check input voltage.
Check limit value.
Check motor protective circuit
breaker.
Contact regional Wedeco Service.
Refer to Chapter Contact Addresses.
Check input voltage.
Check limit value.
Check motor protective circuit
breaker.
Check air condition.
Activate Eco mode on the Rittal air-
condition unit,
refer to manufacturer
manual.
Contact regional Wedeco customer
service.
Refer to Chapter Contact
Addresses.
Check cables and connections.
Refer to manufacturer's
manual.
page 140 of 179