Prior to opening ozone-containing System Components, purge the
system until no more ozone can be detected, however at least 4
hours with nominal gas flow.
Work in which the ozone generator must be opened may only be
carried out by qualified persons.
Ensure sufficient room ventilation.
Do not smoke and avoid open flames.
It is essential to follow the guidelines for handling ozone.
Refer to section Safety.
Escaping oxygen!
Fire hazard (strongly oxidizing)
Ensure sufficient room ventilation.
Do not smoke and avoid open flames.
It is essential to follow the guidelines for handling oxygen.
Refer to section Safety.

9.2 Fault Rectification

The system is equipped with a control unit generating the fault messages. These messages
allow the user to localize non-complex faults and promptly rectify them.
Proceed as follows:
Prior to starting any work on ozone generating components, electrically discharge
them in a safe manner.
Prior to troubleshooting on the system, disconnect the power cable from the power
supply and wait 30 minutes before starting any troubleshooting work.
In the event of a fault message, the ozone production is stopped.
Read the fault message displayed on the HMI.
Rectify non-complex faults promptly.
Prior to fixing more complex faults, read the pertaining technical documents.
After fixing the fault, acknowledge the fault message by means of the system switch
or the pushbutton on the HMI.
Manual_SMOevoPLUS_eng_01.2019.doc
WARNING!
Refer to Chapter Alarms / Events (Current).
Manual Ozone Generating System SMOevo
PLUS
Troubleshooting
page 132 of 179