3.7.2 Precautions

Technical
Ventilation
Ambient Air
Sensor
Cleanness
Breathing
Protective
Devices
Labeling
Residual Ozone
Destruction
Maintenance
Manual_SMOevoPLUS_eng_01.2019.doc
Ensure that rooms housing ozone systems are equipped with a
technical ventilation system guaranteeing an air exchange of at
least three times per hour. An extraction type ventilation system
must be available with the intake opening located directly above
the floor. The ventilation system must turn on automatically when a
gas detector responds to the potential danger.
Minor leaks can result in an ozone concentration in the surrounding
area of the system which is life threatening to people. Therefore, it
is vital to ensure that ozone gas detectors (ambient air sensors) are
installed in this area.
All parts coming into contact with oxygen or oxygen / ozone
mixtures must be free of oil and grease.
Change clothes immediately that have been in contact with oxygen
or oxygen / ozone mixtures or are soiled with grease or oil.
Only enter rooms in which ozone is accumulating or can be
expected to accumulate, wearing a breathing protective device, to
rescue an injured person or to avert acute danger. Store breathing
protective devices only outside of rooms in which ozone systems
are operated. An ozone-proof full mask with an effective filter may
be used as a breathing protection device. Due to the fact that
masks are intended for individual persons, ensure that a mask
identified by the person's name is provided for each person
operating the ozone system.
Ozone supplying pipelines must be marked by appropriate coat of
paint, inscriptions or labels.
Prior to opening the ozone system with gas containing ozone,
purge it until no more ozone can be detected, however at least
4 hours with nominal gas flow.
Ensure that off-gas containing ozone is extracted to the
atmosphere via an effective residual ozone destruction system.
Ensure that the ozone system is serviced by qualified personnel
only.
Manual Ozone Generating System SMOevo
PLUS
Safety
page 27 of 179