5.4.3 Option CP (Custom Positioning)

The option CP includes two skids on which the ozone system is mounted. The skids can be
positioned separately with a maximum distance of 8 m.
This option applies to SMOevo

5.4.4 Option FH (Flashing Light Horn)

Refer to Chapter Subassembly 34: Ambient Air Monitoring.

5.4.5 Option M1 and M2 Ozone Monitoring

The option Ozone Monitoring is available in two versions:
M1
Measurement and display of ozone concentration by ozone monitor HC-400
plus.
M2
Measurement, display, and control of ozone concentration by ozone monitor
BMT 964 C.

5.4.6 Option Z1 Nitrogen Boost

The option Nitrogen Boost includes addition of a low quantity of air or nitrogen respectively to
the pure oxygen.
This option allows a more efficient ozone generation in case of too high oxygen purity.
Refer to Chapter Subassembly 01: Gas Supply.