5.3.2 Subassembly 02: Ozone Generation
02.1.05
Safety valve
02.1.10
Ozone
generator
Manual_SMOevoPLUS_eng_01.2019.doc
Manual Ozone Generating System SMOevo
Opens in case of pressure rise to > 3.5 bar (g) in order to
prevent excess pressure due to thermal expansion in the
ozone generator during operation as well as during OFF state .
In the ozone generator, the oxygenic gas is converted into
ozone according to the silent electrical discharge principle.
Refer to Chapter Ozone Generation Principle.
The setting of the safety valve must not be changed at
•
any time!
PLUS
System Description
page 50 of 179