Drain valve
07.1.35
Butterfly
valve
Option: Converter Cooling SMOevo 610 - SMOevo 860
PLUS
From type SMOevo
cooled too.
07.1.20
Butterfly
valve
07.1.45
Ball valve
07.1.60
Ball valve
07.1.50
Flow meter
07.1.55
3- way
mixing valve
Manual_SMOevoPLUS_eng_01.2019.doc
The setting of the temperature transmitter must not be
changed at any time!
To vent all air from the water cooling system during
commissioning or in case of maintenance or service. Must be
fully closed during normal operation.
Customer interface for cooling water return.
610 on, in addition to the ozone generator, the converter is water
To be throttled to the extent that a sufficient amount of cooling
water is guaranteed for the converter cooling.
Must be fully open.
To display the flow. The flow meter is equipped with a limit-
indicating contact which switches off the system and triggers a
fault message if the value falls below 2l/min (set point =
4l/min).
The 3-way mixing valve allows a continuous flow through both
cooling circuits, and thus a continuous temperature control.
Manual Ozone Generating System SMOevo
PLUS
System Description