Thermo Scientific Partisol 2000i Instruction Manual page 385

Air sampler
Table of Contents

Advertisement

Thermo Fisher Scientific
RS-Para 1
52
ASCII code for the 1-digit Station Number (for example "4": 052). The Station Number is always 1 digit in length.
ASCII code representation of the 2-digit Channel Number (for example: "K0": 075, 048). The Channel Number is
RS-Para 2
75048
always 2 digits in length.
Optional: Up to 3 ASCII codes can be added to response from instrument. In this case, <CR> and <LF> (ASCII
RS-Para 3
13010
codes 013 and 010) are appended to the response. Enter 0 if nothing is to be appended.
RS-Para 4
0
Not used.
Transmission to Instrument
Byte
Example
1
<STX>
ASCII code 002.
2
4
1-digit Station Number, RS-Para 1.
3
S
4
S
4-digit Set Storage Marker
command.
5
T
6
O
7
<space>
Space.
8
K
2-digit Channel Number, as
defined by RS-Para 2.
9
0
10
<space>
Space.
11
B
New location of the Storage
Marker.
12
B: move to beginning of storage
buffer, E: move to end of storage
13
buffer. Enter positive numbers
such as 250 to move forward by n
records, and negative numbers
14
such as -1000 to move backwards
by n records. Do not right-fill.
15
16
<ETX>
ASCII code 003.
17
18
19
AK Protocol
Set Storage Marker Command (SSTO)
COM 2-WAY SETTINGS
Description
B
No Err
1
<STX>
2
3
4
5
6
7
<space>
8
9
<ETX>
10
<CR>
11
<LF>
12
13
14
15
16
17
18
19
Partisol 2000i and Partisol 2000i-D Instruction Manual
Response from Instrument
Error
Description
<STX>
ASCII code 002.
4
4
1-digit Station Number, RS-Para 1.
S
S
S
S
4-digit Set Storage Marker command.
T
T
O
O
Space.
<space>
0
0
Number of current status conditions.
<space>
ASCII code 003.
S
Up to 3 digits appended to the end of
E
the response transmission, according
to the entry for RS-Para 3.
<ETX>
<CR>
<LF>
AK Protocol
Commands List
E-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Partisol 2000i-d

Table of Contents