When you select "Rising" for the edge type, ">" for trigger condition, the
oscilloscope triggers when the positive slope time of the input signal is greater
than the specified time.
When you select "Rising" for the edge type, "<" for trigger condition, the
oscilloscope triggers when the positive slope time of the input signal is smaller
than the specified time.
When you select "Rising" for the edge type, "< >" for trigger condition, the
oscilloscope triggers when the positive slope time of the input signal is greater
than the specified lower limit time and smaller than the specified upper limit
time.
When you select "Falling" for the edge type, ">" for trigger condition, the
oscilloscope triggers when the negative slope time of the input signal is greater
than the specified time.
When you select "Falling" for the edge type, "<" for trigger condition, the
oscilloscope triggers when the negative slope time of the input signal is smaller
than the specified time.
When you select "Falling" for the edge type, "< >" for trigger condition, the
oscilloscope triggers when the negative slope time of the input signal is greater
than the specified lower limit time and smaller than the specified upper limit
time.
Slope Time Setting
In the When item, when ">" or "<" is set to trigger conditions, click or tap the
input field of Lower or Upper to set the lower limit value or the upper limit value
with the pop-up numeric keypad. You can also use the corresponding knob to
set the value. The slope time available is from 100 ps to 10 s.
In the When item, when "< >" is set to trigger conditions, click or tap the input
field of Upper and Lower respectively to set the lower limit value and the upper
limit value with the pop-up numeric keypad. You can also use the corresponding
knob to set the values. The lower slope time limit must be smaller than the
upper slope time limit.
Trigger Mode
In Sweep, select Auto, Normal, or Single as the trigger mode. For details, refer to
Trigger Mode
Trigger Parameter Setting
You can refer to
noise rejection under this trigger type.
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
.
Trigger Holdoff
Noise Rejection
and
Triggering the Oscilloscope
to set the trigger holdoff and
HDO1000 User Guide
75

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdo1072Hdo1074Hdo1102Hdo1104Hdo1202Hdo1204

Table of Contents