ELECTRICAL SYSTEM

Problem
Battery will not hold a
charge.
Low battery power.
Engine speed is not
controllable.
Power mode selector does
not work.

Troubleshooting

Troubleshooting
6
Cause
Low battery power.
Alternator belt loose or bad.
Loose or corroded terminals.
Alternator faulty.
Internal battery short.
Short circuit in wiring.
Speed control dial failed.
Throttle controller failed.
Speed control motor failed.
Blown fuse.
Wiring harness damaged.
Connector failed.
Blown fuse.
Power mode selector switch failed.
Connector failed.
Wiring harness damaged.
e-EPOS controller failed.
Remedy
Clean and retighten.
Tighten or replace belt.
Tighten or replace as required.
Repair or replace as required.
Replace battery.
Repair as required.
Replace control dial.
Replace controller.
Repair or replace as required.
Replace fuse.
Repair or replace as required.
Repair or replace as required.
Replace fuse.
Replace switch.
Replace connector.
Repair or replace as required.
Repair or replace as required.
OP000030
OP000030
6-1