Intermec EasyCoder C4 Programmer's Manual page 17

Bar code label printer
Hide thumbs Also See for EasyCoder C4:
Table of Contents

Advertisement

Example, cont.
Command
FK"TEST"
FS"TEST"
Command
V00,15,N,"Enter Product name:"
V01,10,L,"Enter Model number:"
V02,8,N,"Checked by:"
Command
C0,6,L,+1,"Enter Serial Number:"
Intermec EasyCoder C4 – Programmer's Guide Ed. 3
Name the Form
Name of this form is TEST.
Explanation
CR/LF to start command structure
Delete any existing form named TEST
Start store form named TEST
Defi ne Variables
The fi rst variable (V00) has a maximum size of 15 characters.
The second variable (V01) has 10 characters and prints in reverse.
The third variable (V02) has a maximum size of 8 characters.
Explanation
Defi ne fi rst variable
Defi ne second variable
Defi ne third variable
The text within quotes are prompts, which will be sent from
the printer to the host when the label form is retrieved (serial
communication only).
Defi ne a Counter
The counter has maximum 6 digits.
Explanation
Defi ne counter
Note:
The variables (V00, V01, V02) and counter (C0), are defi ned
within this label form named TEST. The next label form containing
variables and counters, will again start with V00 and C0.
If variable data is being sent from an external data base, omit
the text between the quotes and replace with a space character,
for example V00,15,N," ".
Chapter 5
Editing in Form Edit Mode
16