Intermec EasyCoder C4 Programmer's Manual page 40

Bar code label printer
Hide thumbs Also See for EasyCoder C4:
Table of Contents

Advertisement

C – Counter, cont.
Remarks, cont.
Example
Intermec EasyCoder C4 – Programmer's Guide Ed. 3
The fi eld justifi cation parameter (p
When p
= L, R, or C, the counter value will be printed left, right or centre
3
justifi ed in an area with a width defi ned by p
is selected (p
= N), the fi eld will truncated from the right side so as to not
3
exceed the set maximum fi eld length, which may be useful when using a counter
as input data to a bar code.
If the start value entered, when the form is retrieved for printing, is started by one or
several zeros (0), the entire area specifi ed by p
leading zeros, that is p
Note: If a single counter is stepped up several times on the same form, then
the step value p
must be set to the number of times the counter is used in the
4
form or equivalent to what the step values for the single counter add up to in
this form. A Cn±x command must also be used when designing the actual form.
See the
A
and
B
commands.
This form lets you test fi eld justifi cations by entering various start values
when the form is retrieved for printing. Test various number of digits, with
and without leading zeros.
FK"TEST5"
FS"TEST5"
C0,5,L,+1,"Start value CNT 0"
C1,5,R,+1,"Start value CNT 1"
C2,5,C,+1,"Start value CNT 2"
C3,5,N,+1,"Start value CNT 3"
A50,50,0,3,1,1,N,"Cnt left justifi ed:"
A50,100,0,3,1,1,N,"Cnt right justifi ed:"
A50,150,0,3,1,1,N,"Cnt center justifi ed:"
A50,200,0,3,1,1,N,"Cnt not justifi ed: "
FE
) affects the way the counter will be printed.
3
(fi eld justifi cation) will have no effect.
3
Chapter 7 Commands
(number of digits). If no justifi cation
2
(number of digits) will be padded with
2
39