Setting Up the Printer
Default Setup
Intermec EasyCoder C4 – Programmer's Guide Ed. 3
At delivery, the printers are set up as follows.
Parameter
Command Default Setting
Density
D
Character Set
I
Top of Form backup
JB/JF
Media feed adjust
j
Label Gap Sensor
O
Label Taken Sensor
O
Ribbon End Sensor
O
Char. substitution
oR
Form Length
Q
Label Width
q
Reference Point
R
Print Speed
S
Error Handling
UN/US
Windows Mode
W
Serial Port
Y
Print Direction
Z
The setup will be reset to default values if...
• the printer's fi rmware is upgraded using a fi rmware cartridge, or
• the Feed key is pressed more than 3 seconds in the Dump Mode.
Some commands may also affect the values of other command,
for example if a configuration label is printed (see
commands), the print direction is reset to ZT, and if an
Point command is executed, the label width (see
will be changed.
10
8 bits, code page 0, country code 001
Enabled
136 dots (tear-off/straight-through)
Normal (blockage of light = label)
Disabled
Enabled (not used in pure DT printers)
No substitution
Length 1218, gap 24
832 dots (full width)
X:000;Y000
50 mm/sec. (2 inches/sec.)
Disabled
Disabled
9600 baud, no parity, 8 data bits, 1 stop bit
ZT (Start printing at top of image buffer)