HP 68302 User Manual page 464

Hide thumbs Also See for 68302:
Table of Contents

Advertisement

Step 1. Connect the HP 64700 to the PC
You can connect the HP 64700 to an RS-232 serial port on the PC, the Local
Area Network that the PC is on, or an HP 64037 RS-422 interface that has
been installed in the PC.
To connect via RS-232
To connect via LAN
To connect via RS-422
To connect via RS-232
Set the HP 64700 configuration switches for RS-232C communication.
1
Locate the COMM CONFIG switches on the HP 64700 rear panel, and
set them as shown below.
Notice that switches 1 through 3 are set to 001, respectively. This sets the
baud rate to 19200.
Notice also that switches 12 and 13 are set to 1 and 0, respectively. This sets
the RTS/CTS hardware handshake which is needed to make sure all
characters are processed.