13.7.4 Avoid Logging the Host to a Company Network
Being logged onto a network requires the periodic access to the Ethernet interface by processes
other than the measurement application and can lead to loss of UDP packages.
13.7.5 Use a Dedicated Network
Placing the sensor on a dedicated Ethernet network with no other devices on the network, other
than the host computer, removes data collisions and gives the best network performance.

14. Specifications

14.1 Electrical Specifications
Power Source
DC Power
Notes:
1.
The power supply input is reverse polarity protected. If the power and ground to the power supply
inputs are plugged in reverse, then the reverse polarity protection stops the incorrectly wired supply
input from damaging or powering on the sensor.
14.2 Cable Specifications
14.2.1 P/N 9105-C-ZC22-ZC28-X
Operating Temperature Range (Min-Max)
Note:
1.
14.2.2 P/N 9105-C-ZC27-ZC28-X
Operating Temperature Range (Min-Max)
Note:
1.
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel:+1 919.772.0115 • Fax:+1 919.772.8259 •
Table 14.1—Power Supply
Voltage
Minimum
Nominal
12 V
Table 14.2—9105-C-ZC22-ZC28-X
M8, 6-pin, Female Connector to M12 A-Coded, 8-pin, Male Connector
Parameter
Voltage Rating
Current Rating
IP Rating
The cable is rated IP64 when the cable is connected at both ends. The IP rating of the
cable may exceed the IP rating of the sensor, but the sensor IP rating remains the value
listed in the sensor manual's specifications. For the applicable sensor manual,
refer to
Table
2.1.
Table 14.3—9105-C-ZC27-ZC28-X
M8, 8-pin, Female Connector to M12 A-Coded, 8-pin, Male Connector
Parameter
Voltage Rating
Current Rating
IP Rating
The cable is rated IP67 when the cable is connected at both ends. The IP rating of the
cable may exceed the IP rating of the sensor, but the sensor IP rating remains the value
listed in the sensor manual's specifications. For the applicable sensor manual,
refer to
Table
2.1.
1
Maximum
24 V
30 V
C-93
Power Consumption
Maximum
1.5 W
Value
> 30 V
> 0.25 A
IP64
1
-5°C to 70°C
Value
> 30 V
> 0.25 A
1
IP67
-5°C to 70°C
www.ati-ia.com