Cable Configuration; Pin And Wire Assignments For Connectors - Novanta ATI Axia80 Manual

F/t sensor
Hide thumbs Also See for ATI Axia80:
Table of Contents

Advertisement

Manual, F/T Sensor, Ethernet Axia
Document #9620-05-C-Ethernet Axia-02
3.2 Cable Configuration
Cables can be configured a number of ways; however, the most common configurations are presented
in the following:
Power and Ethernet cable
to the customer application
(ATI P/N 9105-C-ZC28-U-RJ45S-X)
RJ45 Connector for Ethernet
(Branch 2)
Unterminated End for Power
(Branch 1)
(ATI P/N 9105-C-ZC28-ZC28-X-Z2)
Note: Cable lengths are shortened in the figure for reference only.
3.3 Pin and Wire Assignments for Connectors
CAUTION: Ensure the cable shield is properly grounded. Improper shielding on the
cables can cause communication errors and an inoperative Axia sensor.
The following section provides the pin assignment for the connector on the Axia sensor and applicable
connectors on the cables. For supply voltage ratings, refer to the following table or
Specifications. For additional cable technical specifications, refer to
Power Source
DC Power
Notes:
1.
The power supply input is reverse polarity protected. If the power and ground to the power supply
inputs are plugged in reverse, then the reverse polarity protection stops the incorrectly wired supply
input from damaging or powering on the sensor.
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel:+1 919.772.0115 • Fax:+1 919.772.8259 •
Figure 3.1—Axia80/Axia90 Cable Configuration
Figure 3.2—Axia130 Cable Configuration
sensor cable
Table 3.1—Power Supply
Voltage
Minimum
Nominal
12 V
24 V
6-pin Power and Ethernet Cable to the sensor
(ATI P/N 9105-C-ZC22-ZC28-X)
8-pin Power and Ethernet Cable to the sensor
(ATI P/N 9105-C-ZC27-ZC28-X)
Note: Cable lengths are shortened
Axia130 sensor
Power and Ethernet cable
to the customer application
(ATI P/N 9105-C-ZC28-U-RJ45S-X)
Unterminated end for power
(branch 1)
RJ45 connector for Ethernet
Section 14.2—Cable
1
Maximum
30 V
C-14
Axia F/T Sensor and
interface plate with
cable support bracket
(P-clip not shown in this view)
or
in the figure for reference only.
Section 14.1—Electrical
Specifications.
Power Consumption
Maximum
1.5 W
www.ati-ia.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Axia80-m8Axia80-m20Axia80-m50

Table of Contents