Wiring Harness, Battery; Changing The Main Fuse; Removing The Battery - Husqvarna FC 450 2014 Repair Manual

Table of Contents

Advertisement

15

WIRING HARNESS, BATTERY

Changing the main fuse

Warning
Fire hazard
The electrical system can be overloaded if the wrong fuses are used.
-
Use only fuses with the prescribed amperage. Never bypass or repair fuses.
Info
The main fuse protects all power consumers of the vehicle. It is located in the starter relay housing under the air filter box lid.
Removing the battel")'
Warning
Battery acid and battery gases cause serious chemical burns.
Risk of injury
-
Keep batteries out of the reach of children.
-
Wear suitable protective clothing and goggles.
-
Avoid contact with battery acid and battery gases.
-
Keep sparks and open flames away from the battery. Only charge in well-ventilated rooms.
-
In the event of skin contact, rinse with large amounts of water. If battery acid gets in the eyes, rinse with water for at
least 15 minutes and contact a physician.
Preparatory work
-
Switch off all power consumers and switch off the engine.
-
Remove the air filter box lid. (- p. 76)
Main work
-
Take off protection caps
-
Remove the faulty main fuse @ .
Info
I
A defective fuse can be identified by the burned-out fuse wire
8
A spare fuse
is located in the starter relay.
-
Install a new main fuse.
I
Fuse (58011109110) (- p. 203)
-
Check that the electrical equipment is functioning properly.
Tip
I
Insert the spare fuse so that it is available if needed.
-
Mount the protection caps.
Finishing work
-
Install the air filter box lid. (- p. 76)
Preparatory work
-
Switch off all power consumers and switch off the engine.
-
Remove the seat. (- p. 79)
Main work
-
Pull back the negative terminal cover
the battery.
-
Pull back the positive terminal cover @ and disconnect the positive cable from
the battery.
8
-
Detach rubber band
-
Lift out the battery.
O.
O
and disconnect the negative cable from
at the bottom.
105
e.

Advertisement

Table of Contents
loading

Table of Contents