6
FORK, TRIPLE CLAMP

Bleeding and filling the cartridge

Info
Before working with the vacuum pump, carefully read the vacuum pump operating manual.
-
Lubricate O-ring
I
Lubricant (T158) (
-
Push the outer tube upward.
-
Clamp the outer tube in the area of the lower triple clamp.
I
Clamping stand (T1403S) (
-
Tighten the cartridge.
I
Guideline
Cartridge on the outer tube
I
Ring wrench (T14017) (
Mount adjuster � of the compression damping. Mount and tighten the screw.
Guideline
Screw, compression adjuster
Alternative 1
-
Turn adjusting screw of compression damping
rebound damping
-
Turn back counterclockwise by the number of clicks corresponding to the fork
type.
Guideline
Rebound damping
Comfort
201366-10
Standard
Sport
Compression damping
Comfort
Standard
Sport
Alternative 2
Warning
Danger of accident
seriously alter the handling characteristic.
Extreme modifications to the suspension setting may cause a serious
deterioration in the handling characteristic and overload components.
-
-
-
Set the adjusting screws to the position determined before removal.
-
Mount protection cap�-
0
of the cartridge.
r
p. 217)
r
p. 232)
I
M51x1.5
r
p. 230)
M4x0.5
48
clockwise all the way.
Modifications to the suspension setting may
Only make adjustments within the recommended range.
Ride slowly to start with after making adjustments to get the feel of
the new handling characteristic.
I
50 Nm (36.9 lbf ft)
1.5 Nm
(1.11 lbf ft)
G,
and adjusting screw of
14 clicks
12 clicks
10 clicks
14 clicks
12 clicks
10 clicks
34