8

Environmental Requirements

8.1

Ambient Temperature

Table 8-1 Ambient Temperature
Parameter
Temperature
Humidity
8.2

Vibration and Shock Resistance

Table 8-2 Vibration and Shock Resistance
Parameter
Condition
Operating
Vibration
Transportation
(Storage)
Operating
Shock
Transportation
(Storage)
Condition
Operating continuously
Transportation (Storage)
Maximum temperature
gradient (Operation and
storage)
Operations
Transportation (Storage)
Requirement
10°C - 35°C (50°F - 95°F)
-40°C - 70°C (-40°F - 158°F)
20°C/h (68°F/h)
Relative humidity is 10% to
80% with maximum dew
point at 32°C (89.6°F)
Relative humidity is 10% to
93% with maximum dew
point at 39°C (102.2°F), and
the air must be non-
condensing all the time
Requirement
5 - 500 Hz: 0.21 Grms (X, Y and Z axis
and every direction for 15 minutes)
5 - 500 HZ: 2.2 Grms (X. Y and Z axis
and every direction for 10 minutes)
On negative and positive X, Y and Z
axis direction, each axis can stand 100
shock pulses of 2 G in a row and the
period can last for 11 ms at most
On X, Y and Z axis direction, each axis
can stand 1000 shock pulses of 40 G in
a row and the period can last for 6 ms
at most