ELECTRO FREEZE Soft Serve Model 99T-RMT
12.2
Mix Transfer System (MTS) Troubleshooting Tab
PROBLEM
Mix leaks out of
1.
MTS.
1.
Mix transfer
system (MTS)
2.
will not operate.
3.
4. M
5.
6.
7.
MTS will not
1.
Hose broken.
shut off.
2.
Pressure switch stuck in closed position.
3.
MTS relay defective.
MTS cycles on
1.
and off without
2.
dispensing
MTS will not
1.
prime.
2.
3.
4.
50
PROBABLE CAUSE
Transfer hose worn or split.
MTS handle not closed..
Hose not installed properly.
Slide switch defective.
TS relay defective.
Start capacitor defective or motor start
switch defective.
Pressure switch defective.
Motor defective or internal overload
tripped.
Worn transfer hose.
Leak on pressure side of system.
Insufficient supply of mix.
Swing clamp knob loose.
Air hose or air meter not installed.
Hose not installed.
les
REMEDY
1.
Remove cover, clean inside MTS
around rollers with spray bottle
provided. Install new hose. Do not twist
hose.
1.
Close, slide and lock inplace..
2.
Check position – reinstall.
3.
Contact your Electro Freeze Distributor
for service.
4.
Contact your Electro Freeze Distributor
for service.
5.
Contact your Electro Freeze Distributor
for service.
6.
Contact your Electro Freeze Distributor
for service.
7.
Contact your Electro Freeze Distributor
for service.
1.
Replace hose.
2.
Contact your Electro Freeze Distributor
for service.
3.
Contact your Electro Freeze Distributor
for service.
1.
Replace hose.
2.
Contact your Electro Freeze Distributor
for service.
1.
Replenish mix supply.
2.
Tighten knob.
3.
Install air hose/air meter.
4.
Install hose.
184621