12 Troubleshooting Table
PROBLEM
Freezer runs
1.
continually and
product
2.
continues to get
colder.
3.
4.
5.
6.
7.
8.
Poor or slow
1.
product
recovery.
2.
3.
4.
5.
184621
PROBABLE CAUSE
Plunger switch rod engaged.
Plunger not seated in head.
Plunger switch (side or center) out of
adjustment or defective.
Faulty thermostat or bulb not deep
enough in well.
Starter or relay contact points stuck.
Faulty time delay.
Suction pressure too low.
Mechanical timer stuck or faulty.
Worn scraper blade.
Dirty or blocked condenser, restricted
air or water flow – high ambient
temperature.
Thermostat cut-in point out of
adjustment or malfunctioning.
Defective condenser fan motor.
Component or compressor failure.
ELECTRO FREEZE Soft Serve Model 99T-RMT
(continued)
1.
Close plunger completely.
2.
Push plunger down.
3.
Contact your Electro Freeze Distributor
for service.
4.
Contact your Electro Freeze Distributor
for service.
5.
Contact your Electro Freeze Distributor
for service.
6.
Contact your Electro Freeze Distributor
for service.
7.
Contact your Electro Freeze Distributor
for service.
8.
Contact your Electro Freeze Distributor
for service.
1.
Replace scraper blade.
2.
Have condenser cleaned by your
Electro Freeze Distributor; lower
ambient temperature.
3.
Contact your Electro Freeze Distributor
for service.
4.
Contact your Electro Freeze Distributor
for service.
5.
Contact your Electro Freeze Distributor
for service.
REMEDY