12.1 Compressor/Condensing Circuit Troubleshooting Tables
PROBLEM
Discharge
1.
pressure too
high.
2.
3.
4.
5.
6.
7.
Discharge
1.
pressure too low.
2.
Noisy
1.
compressor.
2.
NOTE: Contact your authorized Electro Freeze Distributor for in-
structions prior to warranty compressor replacement.
184621
ELECTRO FREEZE Soft Serve Model 99T-RMT
PROBABLE CAUSE
Water hose kinked or pinched. (water
cooled models)
Water turned off or defective water
regulating valve. (water cooled
models)
Restricted water cooled condenser.
(water cooled models)
Dirty air condenser. (air cooled
models)
Unit location too warm (air cooled
models)
Refrigerant overcharge.
Air in refrigeration system.
Water regulating valve open too wide.
(water cooled model)
Shortage of refrigerant.
Tubing rattles.
Spring broken internally.
REMEDY
1.
Move freezer and adjust hose so it is not
pinched or kinked.
2.
Turn on water, or contact your Electro
Freeze Distributor for service.
3.
Contact your Electro Freeze Distributor
for service.
4.
Contact your Electro Freeze Distributor
for service.
5.
Contact your Electro Freeze Distributor
for service.
6.
Contact your Electro Freeze Distributor
for service.
7.
Contact your Electro Freeze Distributor
for service.
1.
Contact your Electro Freeze Distributor
for service.
2.
Contact your Electro Freeze Distributor
for service.
1.
Contact your Electro Freeze Distributor
for service.
2.
Contact your Electro Freeze Distributor
for service.
49