ELECTRO FREEZE Soft Serve Model 99T-RMT
5
Operator Controls and Indicators
5.6
Reset — Overload
This control protects the beater motor
against failure from an overload condi-
tion by automatically shutting down the
freezer. To restart the freezer properly,
turn the SELECTOR switch to "OFF" and
wait 2-3 minutes. Then depress the red
reset button and turn the SELECTOR
switch back to the "AUTO" or "CLEAN"
position.
5.7
Indicator Light — "ADD MIX"
Figure 5-1
14
When flashing, this light indicates the
mix in the mix container is at a low level
and should be refilled as soon as pos-
sible. Always maintain at least 2 inches
(5 cm) of mix in the tank. For best oper-
ating results keep mix tank full.
6
If the overload trips frequently, your
freezer should be checked for proper
product temperature, overrun and
voltage. Contact your Electro Freeze
Distributor.
7 7 7 7 7
If proper mix level is not maintained,
a freeze-up may occur and cause
damage to the freezer.
If using a "Bag-in'box" mix system,
add mix immediately w en the light
comes on.
(continued)
Important:
Important:
Important:
184621