Rinse Switch; Spinner Motor Fuse; Lexible Spinner Shaft; Reset -Circuit Breaker - ELECTRO FREEZE Compact Series Operator's Manual

Shake freezer
Hide thumbs Also See for Compact Series:
Table of Contents

Advertisement

ELECTRO FREEZE Shake Model CS705
5
Operator Controls
5.2

Prime / Calibrate

5.3
Reset - Circuit Breaker Spinner Motor 3
5.4
Syrup Pump Fuse
5.5
Reset — Circuit Breaker Beater Motor
This control protects the beater motor
against failure from an overload condition
by automatically shutting down the
freezer. To restart properly, turn the
SELECTOR switch (5) to "OFF", wait 2-3
minutes, then depress the reset button
and turn the SELECTOR switchback to
the "AUTO" or "CLEAN" position.
5.6

Selector Switch 6

184592
This push button switch is used for priming
and calibrating the flavor syrups. With the
syrup switch in the "ON" position, the
selector switch (5) in "AUTO" and a flavor
selection (8) made, pressing this button will
activate the pump for that flavor to flush
and prime the flavor delivery line and to
allow calibration of the syrup flow.
This control protects the spinner motor
against failure from an overload condition
by automatically shutting it down. To restart
wait 2-3 minutes, then depress the reset
button.
This holds the AGC fuse for the syrup
pumps.
This three-position switch controls the
operating mode of your freezer.
a.
"CLEAN" (left) — This posi-
tion operates the beater only (no refrig-
eration). Always use this mode when
performing cleaning and sanitizing
operations.
b.
"OFF" (center) — In this
position the beater motor and refrigera-
tion system will not operate.
— continued
2
If the circuit breaker trips frequently,
your spinner mechanism and circuitry
should be checked. Contact your
Electro Freeze Distributor.
4
If the circuit breaker trips frequently,
your freezer should be checked for
proper product temperature, overrun
and voltage. Contact your Electro
Freeze Distributor.
Do not use the "FREEZE" position
with water or sanitizer in the cylinder
— the freezer will be damaged.
position activates both the beater motor
and refrigeration unit. This is the normal
operating position which will maintain a
cylinder temperature of 26° to 28°F (-3°
to -2°C).
Important:
5
Important:
Important:
c.
"AUTO" (right) — This
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs705

Table of Contents