Setting-Out Measurement - Sokkia CX-62 Operator's Manual

Table of Contents

Advertisement

15. SETTING-OUT MEASUREMENT

Setting-out measurement is used to set out the required point.
The difference between the previously input data to the instrument (the setting-
out data) and the measured value can be displayed by measuring the horizontal
angle, distance or coordinates of the sighted point.
The horizontal angle difference and distance difference are calculated and
displayed using the following formulae.
Horizontal angle difference
dHA = Horizontal angle of setting-out data - measured horizontal angle
Distance difference
Distance
Sdist: S-O S = measured slope distance - slope distance of setting-out data
Hdist: S-O H = measured horizontal distance - horizontal distance of setting-
Vdist: S-O V = measured height difference - height difference of setting-out
• Setting out data can be input in various modes: coordinates, horizontal
distance, slope distance, height difference and REM measurement.
• In slope distance, horizontal distance, height difference, and coordinate mode,
registered coordinates can be recalled and used as setting-out coordinates. In
slope distance, horizontal distance and height difference, S/H/V distances are
calculated from the read in setting-out coordinate, instrument station data,
instrument height, and target height.
• EDM settings can be set in the Setting-out measurement menu.
• If not measured or the space is left blank "Null" will be displayed.
If distance or angle of setting-out data is set to "Null" the Distance difference is
automatically set to "Null"
• If the S-O data is set in the display other than <S-O Coord>, when the display
is returned to <S-O Coord>, the data that has been input will be deleted.
Displayed item
out data
data
87