Sokkia CX-62 Operator's Manual page 306

Table of Contents

Advertisement

Sensitivity of levels:
Circular level:
Electronic Circular levels:
Graphic display range
Digital display range
Optical plummet:
Image:
Magnification:
Minimum focus:
Laser plummet (option):
Signal source:
Beam accuracy:
Spot diameter:
Brightness control:
Auto power-off
Operating temperature (no condensation):
Storage temperature range (no condensation):
Dust and water resistance:
Instrument height:
Size (with handle):
Weight (with handle and battery):
*8:
No direct sunlight for using high temparatures of 50 to 60 °C (122 to 140
°F) .
10'/2 mm
6' (inner circle)
±6' 30"
Erect
3X
0.3 m
Red laser diode 635 ±10nm (Class 2 IEC60825-
1 Ed. 3.0:2014/FDA CDRH 21CFR Part 1040.10
and 1040.11 (Complies with FDA performance
standards for laser products except for
deviations pursuant to Laser Notice No.50, dated
June 24, 2007.))
1mm or less (when tripod head height is 1.3m).
ø3mm or less
5 levels
Provided (power cut off after 5 minutes)
-20 to 60 °C (-4 to 140 °F)
-30 to 70 °C (-22 to 158 °F)
IP66 (IEC 60529: 2001)
192.5 mm from tribrach mounting surface
236mm +5/-3mm from tribrach bottom
CX-62:
191 (W) X 181 (D) X 348 (H) mm
CX-65:
191 (W) X 174 (D) X 348 (H) mm
5.4kg (11.9 lb)
298
37. SPECIFICATIONS
*8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cx-65

Table of Contents