Suction Screen Installation; Hydraulic Reservoir Cleaning Procedures; Hydraulic Reservoir Cleaning - Terex R160T Service & Repair Manual

Hide thumbs Also See for R160T:
Table of Contents

Advertisement

Figure 8-23
4. Reach inside the reservoir and unscrew the suc-
tion screen. Remove the suction screen from the
reservoir.

Suction Screen Installation

Figure 8-24
1. Insert the suction screen in the reservoir through
the access cover opening.
2. Reach inside the reservoir and screw the suction
screen into the bottom of the reservoir.
3. Install the access cover assembly. Refer to
Chapter 8. Access Cover Assembly Installation.
4. Add manufacturer-approved hydraulic fluid.
8. Hydraulic Reservoir Disassembly and Assembly

Hydraulic Reservoir Cleaning

Procedures
Cleaning procedures are provided for the following
hydraulic reservoir components.
Hydraulic Reservoir
Hydraulic Reservoir Cleaning
The tools required for hydraulic reservoir cleaning
are listed in Table 8-5. Use manufacturer-
recommended tools whenever possible.
Table 8-5
Tool Name
Combination Wrench
Hot oil can cause personal injury. Make sure the
oil is cool before removing any components or lines.
Remove the oil filler cap only when the engine is
stopped and the machine has been allowed to cool
thoroughly
Collect and contain liquids in a suitable contain-
er. Dispose of all liquids according to local regula-
tions and mandates.
1. Drain the hydraulic fluid. Refer to Chapter 13.
Hydraulic Fluid and Filter Change.
2. Remove the access cover assembly. Refer to
Chapter 8. Access Cover Assembly Removal.
3. Thoroughly wipe out the interior of the hydraulic
reservoir with a magnet and a clean rag.
4. Install the access cover assembly. Refer to
Chapter 8. Access Cover Assembly Installation.
5. Add manufacturer-approved hydraulic fluid.